Skip to content

EMC VPLEX Integration ZenPack

Subscription

This integration is a subscription-based Professional Services engagement. Our Integration Services are offered as subscriptions in order to provide initial setup and ongoing compatibility and maintenance. All standard packages are renewable every 12 months from the date of purchase. Contact Zenoss to request more information regarding this or any other ZenPacks.

Authors

Zenoss Inc.

Maintainers

Zenoss Inc.

Organization

Zenoss Inc.

Name:

EMC VPLEX Integration ZenPack

Release:

1.0

EMC VPLEX Integration ZenPack

About

This ZenPack receives SNMP Traps and transforms them into Zenoss Events. Device modeling and monitoring is provided via SNMP and REST API Connectivity.

Limitations

ZenPack is designed to support the following VPLEX device models: Local and Metro version 5.3

Prerequisites

Prerequisite Restriction
Product Zenoss 4.2.5 or higher
Required ZenPacks ZenPacks.zenoss.ZenPackLib >= 2.1.1 ZenPacks.zenoss.PS.Util >= 1.2.0
Other dependencies None

Features

Device Classes

A new device class /Storage/EMCVPLEX will be added

Configuration properties

Basic device monitoring uses SNMP, for full modeling REST API Credentials must be provided:

  • zEMCVPLEXUsername
  • zEMCVPLEXPassword
  • zEMCVPLEXPort
  • zEMCVPLEXSSL
  • zEMCVPLEXConcurrency
    • The number of concurrent connections allowed to the VPLEX endpoint. (Note: the limit is enforced per-process, so Modeling and Collection may both hit this limit.)
    • Default: 3

Device Monitoring

The following metrics are monitored on the VPLEX Device via SNMP.

  • CPU Idle
  • Heap Used
  • Front End Ports
    • Bytes Read/Write
    • Ops Read/Write
    • Average Read/Write Latency
    • Ops Active
    • Ops Queued
  • Backend Ports
    • Bytes Read/Write
    • Ops Read/Write

Components

  • VPLEX Engine
    • Modeled Attributes
      • family
      • part_number
      • revision_number
      • serial_number
      • wwn_seed
    • Monitoring
      • HealthState
      • OperationalStatus
  • VPLEX Fan
    • Monitoring
      • OperationalStatus
      • SpeedThresholdStatus
  • VPLEX Power Supply
    • Modeled Attributes
      • part_number
      • revision_number
      • serial_number
    • Monitoring
      • OperationalStatus
      • TemperatureThresholdStatus
  • VPLEX Consistency Group
    • Modeled Attributes
      • cache_mode
      • detach_rule
      • recoverpoint_enabled
      • storage_at_cluster
  • VPLEX Storage Volume
    • Modeled Attributes
      • capacity
      • io_status
      • storage_volume_type
      • total_free_space
      • vendor_specific_name
      • storage_array
    • Monitoring
      • OperationalStatus
      • HealthState
  • VPLEX Virtual Volume
    • Modeled Attributes
      • capacity
      • expandable
      • expandable_capacity
      • expansion_method
      • recoverpoint_usage
      • volume_type
  • VPLEX Cluster
    • Modeled Attributes
      • top_level_assembly
      • default_director
    • Monitoring
      • HealthState
      • OperationalStatus
  • VPLEX Extent
    • Modeled Attributes
      • capacity
      • vendor_name
      • storage_volume
      • storage_volume_type
      • system_id
    • Monitoring
      • HealthState
      • OperationalStatus
  • VPLEX Local Device
    • Modeled Attributes
      • capacity
      • expandable_capacity
      • geometry
      • stripe_depth
    • Monitoring
      • HealthState
      • OperationalStatus
  • VPLEX Storage Array
    • Modeled Attributes
      • auto_switch
      • controllers
      • ports
    • Monitoring
      • ConnectivityStatus
  • VPLEXLun
    • Modeled Attributes
      • active_controller
      • alua_support
      • passive_controller
      • visibility
    • Monitoring
      • ConnectivityStatus

Events

This ZenPack uses Transforms to generate the following events from SNMP Traps:

VPLEX Event Code Severity Description
0x8a029033 CRITICAL The on-disk configuration information for the reported device is inconsistent, due to the parent having an invalid type.
0x8a029034 CRITICAL The on-disk configuration information for the reported device is inconsistent.
0x8a029035 CRITICAL The on-disk configuration information for the reported device is inconsistent.
0x8a029036 CRITICAL The on-disk configuration information for the reported device is inconsistent.
0x8a029037 CRITICAL The on-disk configuration information for the reported device is inconsistent.
0x8a029038 CRITICAL The on-disk configuration information for the reported device is inconsistent because a parent device has a blocksize of zero.
0x8a029039 CRITICAL The on-disk configuration information for the reported device is inconsistent.
0x8a02903a CRITICAL The on-disk configuration information for the reported device is inconsistent due to inconsistent child and parent node counts.
0x8a02903b CRITICAL The on-disk configuration information for the reported device has inconsistent sibling IDs.
0x8a02903c CRITICAL The on-disk version configuration information for the reported device is inconsistent.
0x8a02903d CRITICAL The on-disk configuration information for the reported device is inconsistent because different child and parent versions were detected.
0x8a02903e CRITICAL The on-disk configuration information for the reported device is inconsistent because of an unknown parent type.
0x8a02903f CRITICAL The on-disk configuration information for the reported device is inconsistent because the parent's child slot already in use.
0x8a029040 CRITICAL The on-disk configuration information for the reported device is inconsistent due to the proposed and current child versions.
0x8a029045 CRITICAL The on-disk configuration information for one of the devices is inconsistent because the child name exceeds the maximum length.
0x8a029046 CRITICAL The on-disk configuration information for the reported device is inconsistent because there is no noodecount for the parent.
0x8a029047 CRITICAL The on-disk configuration information for one of the devices is inconsistent because a parent ID has an invalid length.
0x8a029048 CRITICAL The on-disk configuration information for one of the devices is inconsistent due to the invalid length of the parent type.
0x8a029049 CRITICAL The on-disk configuration information for one of the devices is inconsistent due to the child node count being exceeded.
0x8a02904b CRITICAL The on-disk configuration information for one of the devices is inconsistent.
0x8a02904c CRITICAL The on-disk configuration information for one of the devices is inconsistent.
0x8a02904d CRITICAL Check the status of the devices to determine which device is not available.
0x8a02904e CRITICAL The on-disk configuration information for one of the devices is inconsistent.
0x8a02904f CRITICAL The on-disk configuration information for one of the devices is inconsistent.
0x8a029050 CRITICAL The on-disk configuration information for one of the devices is inconsistent.
0x8a029051 CRITICAL The on-disk configuration information for one of the devices is inconsistent.
0x8a029052 CRITICAL The on-disk configuration information for one of the devices is inconsistent.
0x8a029053 CRITICAL Check the status of the devices to determine which device is not available.
0x8a029054 CRITICAL The on-disk configuration information for the reported device is inconsistent.
0x8a029055 CRITICAL The on-disk configuration information for the reported device is inconsistent.
0x8a029056 CRITICAL The on-disk configuration information for one of the devices is inconsistent.
0x8a029057 CRITICAL The on-disk configuration information for one of the devices is inconsistent.
0x8a029058 CRITICAL The on-disk configuration information for one of the devices is inconsistent.
0x8a029059 CRITICAL The on-disk configuration information for one of the devices is inconsistent.
0x8a02905c CRITICAL The on-disk configuration information for the reported device is inconsistent.
0x8a029060 CRITICAL The storage volume has become unreachable.
0x8a029061 CRITICAL The storage volume has failed, and there is no mirror of the storage volume.
0x8a026062 ERROR The system lost access to the reported storage volume.
0x8a02606f ERROR Two discovered devices reported the same device name.
0x8a029071 CRITICAL Conflicting device configuration information was found on storage volumes.
0x8a029072 CRITICAL The given storage volume has problems that prevent VPLEX from reading data on it.
0x8a02907a CRITICAL The on-disk configuration information for the reported device is inconsistent.
0x8a02907b CRITICAL The on-disk configuration information for the reported device is inconsistent.
0x8a02307e WARNING The system has lost access to the logging-volume device on which it was maintaining a list of changes to the reported device.
0x8a029089 CRITICAL VPLEX cannot do the necessary sector reassignment, because the reported storage volume has no mirror.
0x8a02308d WARNING If we are currently rebuilding the mirror, we will roll back the write only as far as the block in question.
0x8a029092 CRITICAL All of the mirrors of the specified distributed device had been marked out of date.
0x8a029093 CRITICAL A miki-rebuild has failed because I/O that was part of that rebuild has failed to the local child of a distributed RAID-1.
0x8a02609e ERROR A storage volume has been provisioned to this cluster, even though the storage volume logically belongs to another cluster.
0x8a0290a2 CRITICAL The active meta-volume has become unhealthy and is at risk.
0x8a0260b5 ERROR Manual intervention is required.
0x8a0260be ERROR The automatic detach of the given cluster from the given device was disallowed, in order to preserve consistency on the device and avoid losing data.
0x8a0260bf ERROR The automatic detach of missing clusters from the given device was disallowed based on majority rules, in order to preserve consistency on the device and avoid losing data.
0x8a0290c5 CRITICAL A write to the specified metadata volume has failed.
0x8a0290d1 CRITICAL A conflict has been detected between the views of two or more directors as to which metadata amf should be marked active at a cluster.
0x8a0290dd CRITICAL The same disk has been not only presented to multiple clusters, but claimed at those clusters as well.
0x8a0230df WARNING A disk in a metadata volume has become unreachable or unhealthy, thereby reducing the redundancy of the metadata volume.
0x8a0230e2 WARNING A fixed time has passed after the local cluster last booted, and the active metadata volume has not yet been detected.
0x8a0290e5 CRITICAL Invalid settings were read from the metadata.
0x8a0290e6 CRITICAL Check the status of the devices to determine which device is not available.
0x8a0290e7 CRITICAL Check the status of the devices to determine which device is not available.
0x8a0230e9 WARNING Metavolume is running out of available space.
0x8a0290f4 CRITICAL All the storage-volume(s) supporting this mirror leg are performing very poorly, causing severe degradation in the RAID-1 performance.
0x8a036010 ERROR Ensure the spare pools required to support automatic storage volume replacement exist and contain storage volumes.
0x8a0a300b WARNING Local directors are running different versions of software.
0x8a0a6018 ERROR Several wan-com or local-com messages took longer than the allowed round-trip latency in the past hour.
0x8a459010 CRITICAL An IP network device is no longer present.
0x8a453013 WARNING Link went down on a port, depending on the port role, a physical path to local or remote cluster has been lost.
0x8a459018 CRITICAL An SFP is missing, inserted incorrectly, or faulty.
0x8a45901a CRITICAL The EMC part number of the SFP was not recognized.
0x8a45901c CRITICAL Incoming laser is not detected on an optical Ethernet port.
0x8a45901e CRITICAL One 10Gig Ethernet IO module has defective firmware.
0x8a45301f WARNING One 10Gig Ethernet IO module has firmware version that is earlier than any validated version.
0x8a453022 WARNING Attempts to establish the link is failing continuously.
0x8a456027 ERROR The WAN-COM port is configured with non IPV4 protocol.
0x8a45302e WARNING The last redundant IP path to the specified director is down.
0x8a0e901c CRITICAL A series of transient errors were detected while trying to read or write the given block range of the given storage volume.
0x8a109002 CRITICAL During failure recovery, another disruption occurred, and could not be handled.
0x8a113014 WARNING Recovery from simple director failure took too long.
0x8a183004 WARNING If the director has halted due to a software error, it will be reset automatically; otherwise, manual intervention will be required.
0x8a18901f CRITICAL Either a memory leak has occurred or the VPLEX has exceeded its configuration limits.
0x8a186020 ERROR An internal environment operation failed.
0x8a266032 ERROR The last director with the given cluster id has departed.
0x8a269038 CRITICAL This director is trying to kill the identified director, but the call to do that has failed.
0x8a269039 CRITICAL An internal call to reset another director has failed.
0x8a266040 ERROR A director with a different version of firmware may have been inserted into the cluster.
0x8a266041 ERROR A director with a different version of firmware may have been inserted into the cluster.
0x8a266042 ERROR A director with a different version of firmware may have been inserted into the cluster.
0x8a266043 ERROR A director with a different version of firmware may have been inserted into the cluster.
0x8a269045 CRITICAL The director will be in a partially booted state, which allows a value to be set for director-count.
0x8a266064 ERROR This failure exposes the cluster to a Data Unavailability condition in certain director failure/inter-director link failure scenarios.
0x8a269069 CRITICAL The cluster reporting this event has been unable to establish communication with Cluster Witness Server.
0x8a266073 ERROR Cluster Witness cannot be enabled on systems with more than the supported number of clusters.
0x8a269074 CRITICAL The cluster reporting this event has been unable to receive any guidance from the Cluster Witness Server for the last 10 seconds.
0x8a266078 ERROR There are no known causes for this condition.
0x8a276005 ERROR The non-volatile file system has been corrupted and must be repaired.
0x8a276006 ERROR The non-volatile file system is either not configured or has been corrupted.
0x8a276007 ERROR Create a larger meta-volume with a larger NVOL file system.
0x8a276009 ERROR A write error occurred to the non-volatile storage server and data was not written to disk.
0x8a2d6045 ERROR The failure is due to the limit on number of steps that can be added was reached.
0x8a2d6046 ERROR Tried to allocate structure and failed.
0x8a2d6047 ERROR A logical unit has inconsistent path types.
0x8a2d304f WARNING Target device advertised a behavior which is not supported by the VPLEX initiator.
0x8a2d605b ERROR LuId already has maximum controllers allowed on this array.
0x8a2d307b WARNING A back end Logical Unit has reported an unexpected peripheral qualifier.
0x8a2d307e WARNING An inconsistent ALUA support level has been detected for a logical unit.
0x8a2d608A ERROR This logical unit is reserved by another initiator.
0x8a2d6093 ERROR LU mapping on the back-end array had changed.
0x8a2d6094 ERROR This Initiator-Target connection is failing and is out of service.
0x8a2d309A WARNING This logical unit has been busy more often than is considered acceptable
0x8a2d309e WARNING The array reported an unexpected serial number.
0x8a04900f CRITICAL This is likely indicative of severely degraded hardware and/or fabric condition.
0x8a343017 WARNING The host application or OS requested an invalid transfer size on a Scsi Compare and Write Command.
0x8a343018 WARNING The host application or OS specified an out of range Logical Block Address on a Scsi Compare and Write Command.
0x8a346019 ERROR The VPLEX director had insufficient memory resources to process the Scsi Compare and Write Command.
0x8a34601a ERROR The attempt to start a cache transaction for a Scsi Compare and Write command failed.
0x8a34601d ERROR The VPLEX director had insufficient memory resources to process the Scsi Write Same Command.
0x8a34301e WARNING The attempt to start a cache transaction for a Scsi Write Same command failed.
0x8a34301f WARNING Scsi Write Same command processing is disabled on VPLEX.
0x8a346020 ERROR Host initiator has issued target reset due to slow I/O processing.
0x8a3a9000 CRITICAL An internal software error has occurred, which may be triggered by unexpected changes in the cluster's environment or configuration.
0x8a3a6010 ERROR There are already three instances of the given management command currently running, and more than three are not allowed.
0x8a523001 WARNING A persisted record for a consistency group had a format unrecognized by the system.
0x8a523002 WARNING A persisted record for a volume set property had a format unrecognized by the system.
0x8a523003 WARNING A persisted record for a volume set property had a type unrecognized by the system.
0x8a52601d ERROR The system disallowed the automatic detach of the given cluster from the given volume set, in order to preserve consistency on the volumes in the set and avoid losing data.
0x8a52601f ERROR The system did not allow the automatic majority detach of missing clusters on the given volume set.
0x8a403008 WARNING Crash consistency has been lost on the given async consistency group, due to unplanned loss of data, or inability to write a crash-consistent image.
0x8a40901d CRITICAL The "active-cluster-wins" rule-set has been set on the given consistency group, and the given cluster has departed.
0x8a250018 INFO NDU of the VPLEX has finished successfully.
0x8a256019 ERROR NDU of the VPLEX encountered a problem.
0x8A486197 ERROR The Management Module is not present in the specified slot.
0x8A486198 ERROR The operational state of the management module has changed to faulted.
0x8A48619A ERROR The FC I/O Module is not present in the specified slot.
0x8A48619E ERROR The power supply in the specified slot is in faulted state.
0x8A48926C CRITICAL The input air temperature to the power supply has exceeded the threshold levels.
0x8A4861A0 ERROR The fan in the specified slot has faulted.
0x8A489259 CRITICAL The speed of the fan has dropped below the threshold value.
0x8A4861B9 ERROR The SPS is in a faulted state.
0x8A48925A CRITICAL The temperature of the enclosure has exceeded the threshold and a result of which the director is shutting down.
0x8A4830D7 WARNING The director fault code represents the last hardware operation or a hardware fault.
0x8A4861A7 ERROR A communication failure has been reported while attempting to contact the UPS.
0x8A4861A8 ERROR The state of the I/O Annex is faulted
0x8A4861BB ERROR The UPS is in a faulted state.
0x8A48925D CRITICAL This could be due to faulty serial port on management module, faulty serial cable between the management module and the UPS, faulty UPS or missing UPS in the cluster.
0x8A4830DE WARNING The UPS has a problem with its charging hardware.
0x8A4861A9 ERROR The I/O Module is not present in the specified slot of the I/O Annex.
0x8A4861AB ERROR The Gigabit Ethernet I/O Module is not present in the specified slot.
0x8A48926D CRITICAL The power supply is not present in the specified slot.
0x8A4861AE ERROR The fan in the specified slot is not present.
0x8A489264 CRITICAL Fans in the specified slots are in faulted state.
0x8A4861B1 ERROR The midplane is not present in the specified slot.
0x8A4861B2 ERROR The operating status of the director is faulted.
0x8A4861B3 ERROR The director specified is not present in the engine.
0x8A4861B4 ERROR The state of the FC I/O Module has changed to faulted.
0x8A4861B5 ERROR The state of the Gigabit Ethernet I/O Module has changed to faulted.
0x8A4861B6 ERROR The state of the SSD drive has changed to faulted.
0x8A4861B7 ERROR The SSD drive could not be detected in the director.
0x8A4861B8 ERROR The configuration on the ethernet switch of the management module could not be updated due to a software failure.
0x8A4861C5 ERROR The SSD drive on the director failed.
0x8A48925E CRITICAL The power and environment monitoring process failed due to an internal error.
0x8A489269 CRITICAL An internal hardware error has been detected on one of the directors.
0x8A48926A CRITICAL An internal hardware error has been detected on one of the directors.
0x8A4a31F4 WARNING Management of remote and distributed resources is no longer possible.
0x8A4a61F6 ERROR The Host Certificate will expire within a week.
0x8A4a61F7 ERROR The CA certificate will expire in a week.
0x8A4a91F8 CRITICAL Your CA certificate has expired.
0x8A4a91F9 CRITICAL Your Host certificate has expired.
0x8A4a61FA ERROR A partition on your Management Server has exceeded a critical capacity threshold.
0x8A4a31FB WARNING A partition on your Management Server has reached a high capacity.
0x8a363014 WARNING Some amount of IO failure on a login due to dropped frames.
0x8a369015 CRITICAL Some amount of IO failed because frames timed out.
0x8a369018 CRITICAL A Fibre Channel port is continuously toggling between linkup and linkdown.
0x8a36301a WARNING The RX Power level on a Fibre Channel port is below the low limit and IO timeouts have occurred.
0x8a36901c CRITICAL The EMC part number of the SFP was not recognized.
0x8a36301d WARNING The port is equipped with an SFP with approved EMC part number for this product, but the vendor part number is not on the recognized list.
0x8a363030 WARNING An FC chip detected persistent PCI error.
0x8a363034 WARNING Interface received frames with EOFa (End of Frame Abort) delimiter in the last minute.
0x8a363035 WARNING Interface discarded frame(s) in the last minute.
0x8a363036 WARNING Interface received frames with CRC error in the last minute.
0x8a363037 WARNING Interface received frames with protocol error in the last minute.
0x8a363039 WARNING An FC port is being turned off because RX power low and IO timeout.
0x8a36303a WARNING An FC port's TX power is too low.
0x8a4b9000 CRITICAL The filesystem monitor failed to retrieve the status of one of the filesystems that it was monitoring.
0x8a4b9001 CRITICAL A filesystem has exceeded its usage threshold and is getting low on free space.
0x8A4830D8 WARNING The temperate of the I/O Annex is nearing the error threshold levels due to some environmental conditions.
0x8A4830DB WARNING Conditioning of an SPS has been missed for two cycles.
0x8A4830DC WARNING The fibre channel switch and/or management server are not plugged in to the UPS.
0x8A4861C7 ERROR The I/O Annex is not present in the specified slot.
0x8A4861C8 ERROR An I/O Annex fuse has faulted.
0x8A4861C9 ERROR A fan in the I/O Annex has faulted.
0x8A4830E7 WARNING An internal PROM has become corrupted.
0x8A4861CE ERROR Unable to arbitrate for the top-level I2C mux.
0x8A4861CF ERROR Unable to arbitrate for the I2C bus.
0x8A4861D0 ERROR Unable to configure the top-level I2C mux.
0x8A4861D1 ERROR Configuration of the switches on the I2C bus failed.
0x8A4861D3 ERROR The SCL signal on the specified I2C bus is shorted to ground.
0x8A489265 CRITICAL The temperature of the I/O Annex has exceeded the threshold and a result of which the I/O Annex is shutting down.
0x8A489266 CRITICAL Both fans in the I/O Annex have faulted.
0x8A4830E9 WARNING The specified FRU cannot be accessed.
0x8A4861D6 ERROR The specified FRU is not present.
0x8A4861D7 ERROR The state of the specified FRU is faulted
0x8A4830EA WARNING Memory configuration error has been detected.
0x8A4830EB WARNING An internal hardware error has been detected.
0x8A4830EC WARNING An error occurred accessing an NVRAM log.
0x8A4861DA ERROR An SPS conditioning cycle has failed because the battery can no longer hold a sufficient charge.
0x8A4E9002 CRITICAL The cluster has started vaulting either because user initiated a manual vault or due to a persistent power and/or environmental conditions.
0x8A4E900D CRITICAL Vault recovery on the cluster cannot proceed because all director(s) required to complete recovery are either not operational or communicating.
0x8A4E9015 CRITICAL The director(s) in the cluster are taking more than expected time to quiesce IO and freeze the cache for vaulting.
0x8A4C9259 CRITICAL GeoSynchrony has failed three times continuously.
0x8A4C925A CRITICAL GeoSynchrony has failed due to an internal error.
0x8a519001 CRITICAL Errors have been detected that prevent the director from starting fully.
0x8a519002 CRITICAL Errors have been detected that prevent the director from starting fully.
0x8a519003 CRITICAL Errors have been detected that prevent the director from starting fully.
0x8A4A3002 WARNING Automated meta-volume backup has not been properly configured, or the configuration file was removed.
0x8A4A3003 WARNING One, or both, Storage volumes reserved for automated meta-volume backup are used by manually created meta-volume backups.
0x8A4A6007 ERROR Detected incorrect number of storage-volumes configured for automated meta-volume backup.
0x8A4A6006 ERROR The automated backup of the meta-volume could not be completed.
0x8a543013 WARNING A communication port didn't reach link up in time.
0x8a543019 WARNING The last redundant FC path to the specified VPLEX WAN-COM port is down.
0x8a54601b ERROR Stuck IO had been detected on an FC port.
0x8a54301d WARNING Large number of i/os have timed out on this connection in the past one minute.
0x8a559001 CRITICAL A service has stopped running because it has encountered multiple failures.
0x8a556002 ERROR A service has stopped running because it has encountered multiple failures.
0x8a4A6067 ERROR The queue of call-home events being processed hit the length of the queue.
0x8a4A0065 INFO Attempting to resume normal monitoring
0x8a4A0066 INFO Attempting to resume normal monitoring
0x8a343022 WARNING Scsi xcopy command processing is disabled on VPLEX.
0x8a346026 ERROR A xcopy command was aborted because of a system memory allocation failure.
0x8a346027 ERROR A xcopy command was aborted because of a slab memory allocation failure.
0x8a349035 CRITICAL An IO failed to complete or be properly aborted and cleaned up.

Impact diagram v1

EMC Vplex internal impact diagram(EMC Vplex device and components)

[VplexDevice]-impacts>[Engine]

[VplexDevice]-impacts>[Cluster]

[Engine]-impacted by>[Fan]

[Engine]-impacted by>[PowerSupply]

[Engine]-impacted by>[VplexDevice]

[Fan]-impacts>[Engine]

[Fan]-impacted by>[PowerSupply]

[PowerSupply]-impacts>[Fan]

[PowerSupply]-impacts>[Engine]

[ConsistencyGroup]-impacted by>[Cluster]

[StorageVolume]-impacts>[Lun]

[StorageVolume]-impacted by>[StorageArray]

[VirtualVolume]-impacted by>[Extent]

[Cluster]-impacted by>[VplexDevice]

[Cluster]-impacts>[StorageArray]

[Cluster]-impacts>[ConsistencyGroup]

[Extent]-impacts>[VirtualVolume]

[Extent]-impacted by>[StorageVolume]

[StorageVolume]-impacts>[Extent]

[Extent]-impacted by>[LocalDevice]

[LocalDevice]-impacts>[Extent]

[StorageArray]-impacts>[StorageVolume]

[StorageArray]-impacted by>[Cluster]

[Lun]-impacted by>[StorageVolume]

Changelog

  • 1.1.0
    • Add REST based modeling and monitoring.